Site logo
L15C
15 Amp Load Control / Low Voltage Disconnect 12V or 24V

Protect your batteries from over-discharge.

When first turned on, if the IN voltage is above the Off set point the load will turn on.

When the input voltage is at or below the Off set point for 60 seconds the output turns off. The off set point is adjustable from 11.2V to 12.4V.

When the input voltage is at or above the On set point for 60 seconds the output turns on. The On set point is approximately 1 volt above the off set point.

The 8 position switch allows adjustment of the low voltage set point, including an On position. Includes 15 Amp fuse and holder.

Custom voltage set points and time delays can be ordered.

Replacement for Rogue 1950-222

Load
Model: L15C

Features

• Extreme design –40° to +50°C (-40° to +120°F)
• Reliable - 100% solid state
• Fully encapsulated in epoxy potting
• 5 year warranty
• Designed and built in North America

Electrical Specifications
Voltage configurations 12 or 24 volts (custom voltages 6 to 60 volts)
Max. input 40 volts (60V for 24V version)
Max. Current 15 amps DC
Typical battery consumption 2.5 mA when Load on, 0.6 mA Load off

General Specifications
Temperature range: –40° to +50°C or +120°F
Case: ABS case, completely sealed in epoxy
Weight: 3.5 oz, 100 grams
Size(H x W x D): 5.1 x 5.1 x 3.8 cm (2 x 2 x1.5 inches) not including rotary switch or mounting tabs
Wire: 16 tinned gauge leads 5 inches long
Mounting: wall mountable

Options
Voltage setpoints
Time delays
Trim adjustment on back of the control
Custom wire lead lengths
Temperature Compensation
Status Light: 1 LED (1 flash - low set point, 2 flashes - Off, 3 flashes - Low & Off)
Lithium Battery (no discharge below 4C)
Output ON when the voltage is low

Installation Manual
L15-C

VOTLAGE